Operation
34
The coolers have an integrated multi-voltage power supply with
priority circuit for connecting to an AC voltage source of 100–240 V.
The priority circuit automatically switches the cooler to mains oper-
ation, if the device is connected to a 100–240 V AC mains, even if
the 12/24 V connection cable is still attached.
When switching between the AC mains and the battery supply,
the red LED may light up briefly.
Plug the 100240 V connection cable (fig. 1 3, page 3) into
the AC voltage socket and connect it to the 100240 V AC
voltage mains.
6.4 Using the battery monitor
The device is equipped with a multi-level battery monitor that
protects your vehicle battery against excessive discharging when
the device is connected to the on-board 12/24 V supply.
If the cooler is operated when the vehicle ignition is switched off,
the cooler switches off automatically as soon as the supply voltage
falls below a set level. The cooler will switch back on once the
battery has been recharged to the restart voltage level.
a
Caution – Danger of damage!
When switched off by the battery monitor, the battery will no longer
be fully charged. Avoid starting repeatedly or operating current
consumers without longer charging phases. Ensure that the battery
is recharged.
In “HIGH” mode, the battery monitor responds faster than at the
levels “LOW” and “MED” (see the following table).
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10.1 V 11.4 V 11.8 V
Restartvoltage at 12 V
11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V
21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.0 V 25.3 V 26.2 V